VENTS VUT 350 VB EC A14 HŐVISSZANYERŐ
Leírás
Alkalmazási példa:

Vezérléssel:

Működési elv:

Jelleggörbe:

Méretek:

|
Sizes |
∅D |
B1 |
H |
H1 |
L |
L1 |
L2 |
|---|---|---|---|---|---|---|---|
|
mm |
160 |
592 |
758 |
675 |
775 |
426 |
230 |
Műszaki adatok:
|
Parameter |
Value |
Unit |
|
|---|---|---|---|
|
Phase |
1 |
˜ |
|
|
Unit voltage |
220-240 |
V |
|
|
Frequency |
50/60 |
Hz |
|
|
Maximum fan power |
166 |
W |
|
|
Fan current |
1.3 |
A |
|
|
Maximum air capacity |
415 244,435 115,37 0,11537 6930,5 |
m³/h CFM l/s m³/s l/m |
|
|
RPM |
3200 |
min -1 |
|
|
Sound pressure level at 3 m |
28 |
[dBA] |
|
|
Casing material |
polymer coated steel |
||
|
Maximum transported air temperature |
-25 +60 |
оC |
|
|
Insulation |
40 mm, mineral wool |
||
|
Connected air duct size |
160 |
mm |
|
|
Weight |
66 |
kg |
|
|
Filter: extract |
G4 |
||
|
Filter: supply |
G4 (F7*) |
||
|
Heat recovery efficiency |
85 up to 98 |
up to % |
|
|
Heat exchanger type |
counter-flow |
||
|
Heat exchanger material |
polysterene |
||
|
ЕС- motor |
yes |
||
|
Type |
air handling units with heat recovery |
||
|
Heat recovery |
yes |
||
|
SEC Class |
A+ |
||
Vents VUT 350 VB EC Használati útmutató